Hardware and software implementation of a platform (a pedestal) with two trapdoors that open at random.

This is a laboratory apparatus used to simulate ankle sprain in a person standing on the pedestal, for research purposes.

The trapdoors are electronically opened under software control to ensure double-blind trials: neither the subject nor the operator know when nor which trapdoor will open. The actuation mechanism is silent and almost instaneous to avoid giving early warning cues.

Trapdoor opening instants are encoded in an analog electronic signal, which can be recorded with standard surface electromyography (sEMG) equipment, for synchronization purposes.

PT:
Implementação em hardware e software de uma plataforma (um pedestal), com dois alçapões que se abrem ao acaso.

Este é um aparelho de laboratório usado para simular entorse de tornozelo numa pessoa de pé no pedestal, para fins de investigação.

Os alçapões são abertos eletronicamente sob controle de software para garantir ensaios duplamente cegos: nem o sujeito nem o operador sabem quando nem qual alçapão se abrirá. O mecanismo de atuação é silencioso e quase instantâneo para evitar dar pistas de alerta precoce.

Os instantes de abertura dos alçapões são codificados num sinal electrónico analógico, que pode ser gravado com equipamentos comuns de electromiografia de superfície, para fins de sincronização.